(at the controller & devices).
(To the cable).
68 PIN HI-DENSITY D-SUB FEMALE at the controller & devices.
68 PIN HI-DENSITY D-SUB MALE at the cable.
| Pin | Name | Dir | Description |
|---|---|---|---|
| 1-16 | GND | Ground | |
| 17 | TERMPWR | Termination Power | |
| 18 | TERMPWR | Termination Power | |
| 19 | res | reserved | |
| 20-34 | GND | Ground | |
| 35 | DB12 | Data Bus 12 | |
| 36 | DB13 | Data Bus 13 | |
| 37 | DB14 | Data Bus 14 | |
| 38 | DB15 | Data Bus 15 | |
| 39 | DPB1 | Data Parity (odd Parity) | |
| 40 | DB0 | Data Bus 0 | |
| 41 | DB1 | Data Bus 1 | |
| 42 | DB2 | Data Bus 2 | |
| 43 | DB3 | Data Bus 3 | |
| 44 | DB4 | Data Bus 4 | |
| 45 | DB5 | Data Bus 5 | |
| 46 | DB6 | Data Bus 6 | |
| 47 | DB7 | Data Bus 7 | |
| 48 | DPB | Data Parity (odd Parity) | |
| 49 | GND | Ground | |
| 50 | GND | Ground | |
| 51 | TERMPWR | Termination Power | |
| 52 | TERMPWR | Termination Power | |
| 53 | res | reserved | |
| 54 | GND | Ground | |
| 55 | /ATN | Attention | |
| 56 | GND | Ground | |
| 57 | /BSY | Busy | |
| 58 | /ACK | Acknowledge | |
| 59 | /RST | Reset | |
| 60 | /MSG | Message | |
| 61 | /SEL | Select | |
| 62 | /C/D | Control/Data | |
| 63 | /REQ | Request | |
| 64 | /I/O | Input/Output | |
| 65 | DB8 | Data Bus 8 | |
| 66 | DB9 | Data Bus 9 | |
| 67 | DB10 | Data Bus 10 | |
| 68 | DB11 | Data Bus 11 |
Note: Direction is Device relative Bus (other Devices).
| Contributor: | Joakim Ögren |
| Source: | SCSI FAQ |
| SCSI 68 Pin Normal pinout at The Pin-Out directory |